Used Medical Imaging
7,374 resultsSW Version vb19 Z440 WK model Gradient strength 1500 G/CM Coils: 7 channel breast, 8 channel knee, TIM total s Year(s) : 2006 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsX-Ray Tube E72-3912X Digital DF X-Ray Panel The System is NOT Installed Year(s) : 2008 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsGamma Camera Model BrightView Year(s) : 2010 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsOBI(KV-On Board Imager) v. 1.6.20.0 CBCT (Cone Beam CT) v. 02.01.05 VVMAT/VMAT Application Installed Millenniu Year(s) : 2008 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsOBI (KV- On Board Imager) CBCT (Cone Beam CT) RapidArc/VVMAT Application Installed aS500 (E-Arm) Portal Imagin Year(s) : 2008 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsMillennium 160 Leaf MLC 6&15 Mv Photon Energies Klystron System comes with: TxT table, Assorted spare parts, Year(s) : 2010 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsLinear Accelerator Model Clinac IX-S Year(s) : 2011 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsBrand IntraOp Manufactured in 2012 System is Installed and Clinically Operational Available Now Year(s) : 2012 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsPositioning Lasers Non-indexed Flat-Table Top Included: Complete Set of Accessories Year(s) : 1994, 2010 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsPreformix X-Ray Tube Possible Software Options: PET 2D, Card IQ Snap Shot, PET Base, Power 440, Direct-3D, Year(s) : 2003, 2008 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsTube replaced August 2022 Year(s) : 2004 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsMagnet Manufacturer GE Magnet Type: Electro/Permanent Magnet Age: 19 years Gradient Strength M/T: 20 Shielding Year(s) : 2001 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsDOM: May 2011 First installation: 2011-11-11 Tube details: YOM: 2021 Date installed: August 2021 Model: Pe Year(s) : 2011 Location : EUROPE (Western and Northern)
Price : On request
More detailsHighlights MR Software Release SV25.1_2131a XGD SR 120 with 8920 Gradient Amplifier 32 RF-Channels Sumitomo F- Year(s) : 2012 Location : EUROPE (Western and Northern)
Price : On request
More detailsDefinition AS – 64 slice syngo CT VA48A Date of Manufacturing: 2014 Tube: Straton MX-P, 473k ss (at removal) T Year(s) : 2014 Location : EUROPE (Western and Northern)
Price : On request
More detailsYOM 2015 Slices: 80 Tube model: CXB-750G / MCS-7178A Tube YOM: 2021 Tube count: ~348k ss at QA SW Options: AL Year(s) : 2015 Location : EUROPE (Western and Northern)
Price : On request
More detailsSub-modality: C-arm Machine YOM: 2008 Software Version: 2.2.6 Tube Model: FO 10 – 110 kV Tube YOM: 2008 HW Acc Year(s) : 2008 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsSub-modality: Cath Lab YOM: 2008 Software Version: 7.2.16 Tube YOM: 2016 Single Plane / Biplane: Single Plane Year(s) : 2008 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsSub-modality: Cath Lab Software Version: 8.1.3.5 Tube Model: MRC 200 0508 Tube YOM: 2018 Detector Type + size: Year(s) : 2012 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsRECENTLY DEINSTALLED FROM SIEMENS RAD ROOM 2017 KONICA AERO DR PERFORMANCE DR COMPLETE SYSTEM Year(s) : 2017 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More details06' GE Millenium MG Nuc Med Scanner SW Version: 2.1753 Available early Apr. Year(s) : 2006 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsINCLUDING REMOVAL ONTO YOUR TRUCK LOADED WITH SW 2025 TUBE WITH 16M MAS 2009 LightSpeed VCT 64 Console: NIO64 Year(s) : 2009 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsCOMPLETE TABLE PACKAGE: MOTORIZED ELEVATION TRENDELENBURG TILT MANUAL TABLETOP FLOAT CATHETER TRAY RAIL MOUNTE Year(s) : 2018 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsGE HDXT 23X , 8CH MOBILE MRI HDXT PLATFORM (UPGRADED BY GE IN 2014) 2014 SYSTEM CABINETS HD 23.0.V02 SW LEVEL Year(s) : 2000 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsGantry AWS8000 (Win10) Lead Glass Shield Slide Face Shield X-Ray Tube Digital Detector Detector/Array Mapping Year(s) : 2016 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsYou can find used Medical Imaging on Wotol
The main manufacturers of Medical Imaging are GE, Siemens, Philips, Toshiba, OEC, GE Healthcare, Hologic, Hitachi, Konica, Fuji Film, Fuji, Shimadzu, Ziehm, Agfa, Esaote.
The main models are Aquilion 16, 9800, LightSpeed 16, SOMATOM, Sensation 64, AMX4, 9900 Elite, LightSpeed VCT, 600CD, Discovery CT750 HD, Trilogy Linear Accelerator, BV Libra, Definition AS20, AQUILION 64, LightSpeed VCT 64, Optima 660, Optima 360, Lunar Prodigy, AVANTO 1.5T, Emotion 16, MAGNETOM Symphony 1.5T, 9800 9in, 9900 Elite 9in, VANTAGE TITAN 1.5Т, AQUILION CXL 128, DRYPIX1000, DRYPIX 7000, FCR Speedia CS.
Questions and answers between users
Q: What is the benefit of a 3T MRI scanner compared to a 1,5 MRI scanner?
A: A 3T MRI scanner is twice more powerfull than a 1.5T MRI.
3T is ideal for imaging of small bones, breast MRI, musculoskeletal MRI, neurological MRI and vascular MRI, where the smallest details are particularly crucial for diagnosis. However, a 3T machine is not always the best for all types of imaging. 3T has a higher probability of artifacts. An artifact is any object that appears in the image that is not in the original object. These can show up in MRI images as “flow” artifacts due to the movement of blood or fluid. A 3T machine also creates additional heat and more noise compared to a 1.5T. 3T MRI scanner has a field strength twice as powerful as a 1.5T MRI
A 1.5T machine is ideal for MRI scans of the abdomen and chest. A 3T machine will provide extremely clear and vivid images. Plus, they can often be done faster, reducing overall scan time.
Last point, a 3T MRI is about 50% more expensive than a 1.5T
Q: What does the DR and NX stand for the Agfa workstation linked with CR85-X multi-user digitizer.
A: The DX is the software thet controls the WiFi sensors while the NX sofware is for the numerical plates.