Used IR Spectrometers and others type
114 resultsWith Omnic Spectra Softre. Sample holder and lid for transfer. New laser installed in 2022. Location : EUROPE (Western and Northern)
Price : On request
More detailsWith 2x contact measuring heads PSS-H-B01. Optical fiber PSS-F, fiber length 1x 0.5m and 1x 30m with a spectra Year(s) : 2019 Location : EUROPE (Western and Northern)
Price : On request
More detailsCombines the precision of polarization FT technology with the cleanliness requirements in the production envi Year(s) : 2017 Location : EUROPE (Western and Northern)
Price : On request
More detailsWith cover. Plug. Software minispec CD for Windows 7. Location : EUROPE (Western and Northern)
Price : On request
More detailsThermo-Nicolet PROTÉGE-460 FTIR Spectrometer This PROTAGE-460 FTIR has equipped with a KBr Beam Splitter, D Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsOverall Size 500mm X 450mm X 350mm Tall Location : EUROPE (Western and Northern)
Price : On request
More detailsIncl. Rondelle for 30 samples. Spectral range 800-1900nm 230V. 50 / 60Hz. 1.6A. Device is in good condition. Location : EUROPE (Western and Northern)
Price : On request
More detailsSpectral range: 12,000 to 3,800 cm-1. Wavelength 833 to 2,630 nm. Halogen-NIR source. Laser class 1. Includes Location : EUROPE (Western and Northern)
Price : On request
More detailsFor precise analysis of fat, protein, lactose, dry matter and raw milk, cream, whey or yoghurt products. Measu Location : EUROPE (Western and Northern)
Price : On request
More detailsA mint compact sensitive easy to use system with a built in printer- ships with new lamp in this 150 watt xen Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsSpectroflourometer with Temperature Control, incoming, a nice compact unit Very sensitive, with temperature co Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsLocation : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsDisplay Mode: Optical Rotation Sptical Rotation, Specific Rotation Concentration, Sample holder Record output, Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailswith SpectrAA v5.2 PC workstation OPTIONAL: Varian VGA77 vapor generator (VGA-77) & Agilent mercury lamp (p/n Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailscomplete with chiller, autosampler and PC workstation Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsOPTIONAL: Agilent GTA 120 Graphite Tube Atomizer (p/n AA1105M547) & Agilent Technologies PSD 120 Programmable Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsRefurbished Shimadzu AA-7000 double beam Atomic Absorption Spectrophotometer Complete with Shimadzu WizAArd 5 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsNanoDrop ND-1000 Spectrophotometer Computer Cables and connectors Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsLocation : EUROPE (Western and Northern)
Price : On request
More detailsLINE IS DISMANTLED. Fully automated anodising line. Material dimensions of up to 1,5 x 1,4 x 0,5m to be anodi Location : EUROPE (Central and Eastern)
Price : On request
More detailsFEATURES Wave number range 4000 to 600 cm EZ-scan software for instrument control and data acquisition 2 cm-1 Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsmass spectrometer complete with Turbo V-Source with ESI Probe, Varian Vacuum Pump with hose custom bench on wh Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailscomplete with THGA-700 transverse heated graphite atomizer Perkin Elmer furnace cooling system (p/n 198072) an Location : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsLocation : AMERICA North (USA-Canada-Mexico)
Price : On request
More detailsLight Source: Tungsten Halogen Spectral Bandwidth: 4nm Wavelength Range: 320-1100nm Specifications Stray light Location : EUROPE (Western and Northern)
Price : On request
More detailsYou can find used IR Spectrometers and others type on Wotol
The main manufacturers of IR Spectrometers and others type are Perkin Elmer, Thermo Nicolet, Jasco, Foss, Nicolet, Bruker, Shimadzu, Thermo Electron, Varian, Agilent, Thermo, Alere, Magna.
Find the right Spectrophotometer or Instrumental color measurement with our expert
This instrument has lens, light source, difraction gratting or prism and color analyser.
What is "Color" ? When we see the object and then we say the color is Blue , do you know why ?
It is because object reflected Blue color and adsorb other color. To see colors we need: Object, illuminant (light source), observer (Eyes or Lens) and then Brain or Analyser will calculate so we have "Color"
Our eyes always see what refelected by object. Similar case with Spectrophotometer it can measure reflectance and transmitance.
The next step would be the physical measurement of the
object, for reflected (or transmitted) light, by a color spectrophotometer. The basic information provide by the “spectro” is simply the wavelength reflectance values across the visible spectrum, known as spectral data, which can be displayed as a spectral curve.
Now 2 of the 3 elements of the observer situation are represented as numbers.
Spectral reflectance data
- Spectral measurement range:
380nm to 730nm
- Reflectance range
"Normal" samples: 0% to 100%
(100% = perfect white diffusor 0% = perfect black)
Effect samples: up to 300% (for small aspecular angles)
Fluorescent colors: up to 200%
Color identification
Spectral information under defined geometrical conditions is the fingerprint of a color
The spectral information can be transformed so that colors can be arranged in a 3 - dimensional color space
Every color has a unique "address" color space
The "address" is valid for a certain illuminant (D65 or A or TL84 or others) and for a certain observer (2° or 10°) and for a certain geometry (d/8°, 45°/0° or others) !
Changing illuminant and/or observer and/or geometry in most cases will result in a different "address" in color space for the same sample
Color order system, color space
CIE L*a*b* 1976
Based on the Munsell system
L* a* b* are the primary coordinates
L*: Lightness direction
a*: red - green direction
b*: yellow - blue direction
CIE Lab system is industry standard
CIE Lab system version 2
C*, h: Same facts, different description
polar coordinates instead of kartesian coordinates
Chroma (independent of hue)
C*= (a*2 + b*2) 1/2
Hue angle (independent of chroma)
h= arctan (b* / a*) counterclockwise, starting at positive a* axis with h = 0°
Color difference description
Most important for industrial use
Color difference is the distance in color space between two adresses", e.g. between the "adress" of a standard and the "adress" of a trial.
The color difference has 3 components:
Lightness difference dL*=L*trial - L*standard
red-green difference da*=a*trial - a*standard
yellow-blue difference db*=b*trial - b*standard
Total color difference dE* is calculated from the 3 components:
dE*= (dL*2 + da*2 + db*2) 1/2
Same facts, different description
dE*= (dL*2 + dC*2 + dH*2) 1/2
Chroma difference dC* = C*trial - C*standard
Hue difference dH*= (da*2 + db*2 - dC*2) 1/2
sign dH*: positive if
a*trial b*standard - a*standard b*trial R0 else negative.
Attention: dH* is a distance in color space and not the difference of the hue angles htrial - hstandard !!!
But the computer has no problem with the slightly complicated calculation
Common brand:
Datacolor, GretagMacbeth, Hunterlab, Kurabo, Macbeth, Minolta and Xrite